lint(standard): corrections completes mode standard

- Em dashes: 1712 remplaces par tirets simples (86 fichiers + _index.md,
  en-tete section Limagrain conserve)
- Checklists: 24 '- [ ]' -> '- ☐' (3 pages operations, plus de todos Obsidian)
- Ancres: 33 reparees (slugs GitHub + ancres HTML <a id> reconnues),
  1 reciblee (manuel de reten)
- related: tenseflow -> tense-flow, pie -> mechanical-elements,
  group.md retire (doublon shipping)
- Registre: compteur global 122 -> 131 pages
- Rapport racine _lint_report.md mis a jour (scan v2 + re-scan final: 0 anomalie)
- Aucun fichier limagrain/ modifie (cloisonnement)
This commit is contained in:
2026-07-20 13:01:21 +02:00
parent 7496aafe64
commit 9ce6ae37be
88 changed files with 1769 additions and 1871 deletions
+9 -9
View File
@@ -29,7 +29,7 @@ The Automation Dashboard module (sourced from the `faults_management` area) prov
The module ensures complete traceability of machine status and problems, enabling supervisors to respond quickly and maintain audit trails.
**Note**: The `areas/automation_dashboard/` folder returns 404 the Automation Dashboard functionality is implemented in `areas/faults_management/`.
**Note**: The `areas/automation_dashboard/` folder returns 404 - the Automation Dashboard functionality is implemented in `areas/faults_management/`.
## Key capabilities
@@ -122,11 +122,11 @@ Faults most often seen on miniload installations. Use this table to triage befor
| **1201** | Variator fault X | Variator hardware fault on axis X |
| **1291** | Unreferenced SM302 card on the variator | Warning only |
Fault 1116 is the configuration-drift counterpart of `EndErrorCode=4` seen in Gateway logs same root cause, different reporting surface.
Fault 1116 is the configuration-drift counterpart of `EndErrorCode=4` seen in Gateway logs - same root cause, different reporting surface.
## Reference reports
Standard Automation Dashboard reports delivered by Mecalux (documents on [Confluence Automation Dashboard](https://easywmsfrance.atlassian.net/wiki/spaces/EF/pages/3001220136988)):
Standard Automation Dashboard reports delivered by Mecalux (documents on [Confluence - Automation Dashboard](https://easywmsfrance.atlassian.net/wiki/spaces/EF/pages/3001220136988)):
- Module presentation
- Machine availability report (per machine)
@@ -135,9 +135,9 @@ Standard Automation Dashboard reports delivered by Mecalux (documents on [Conflu
## Related
- [[agv]] AGV machine faults and manual actions are tracked in the Automation Dashboard
- [[aps3d]] APS3D Fleet Manager and cart faults tracked for traceability
- [[task]] Manual task completions and modifications logged as actions
- [[stations]] Machine stations are the physical entities tracked in the dashboard
- [GALILEO Integration](../architecture/galileo-integration.md) protocol layer that produces many of the faults tracked here
- [Galileo Troubleshooting](../operations/galileo-troubleshooting.md) log-level diagnosis
- [[agv]] - AGV machine faults and manual actions are tracked in the Automation Dashboard
- [[aps3d]] - APS3D Fleet Manager and cart faults tracked for traceability
- [[task]] - Manual task completions and modifications logged as actions
- [[stations]] - Machine stations are the physical entities tracked in the dashboard
- [GALILEO Integration](../architecture/galileo-integration.md) - protocol layer that produces many of the faults tracked here
- [Galileo Troubleshooting](../operations/galileo-troubleshooting.md) - log-level diagnosis